Parameter H300
Operational envelope 150 - 4000 m AGL, nominal
Laser wavelength 1064 nm
Horizontal accuracy 1/5,500 x altitude, 1 σ
Elevation accuracy <3-15 cm; 1 σ
Effective laser repetition rate Programmable, 50-300 kHz
Position and orientation system POS AV™ AP50 (OEM) 220-channel dual frequency GPS/GNSS/Galileo/L-Band receiver
Scan width (FOV) Programmable, 0-50°
Scan frequency 6 Programmable, 0-90 Hz
Sensor scan product 1000 maximum
Beam divergence 0.25 mrad (1/e)
Roll compensation Programmable, ±30° (FOV dependent)
Vertical target separation distance <0.7 m
Range capture Up to 4 range measurements, including 1st, 2nd, 3rd, and last returns
Intensity capture Up to 4 intensity returns for each pulse, including last (12 bit)
Data storage Internal solid state disk SSD (SATA II); Removable SSD (optional)
Image capture Compatible with full Optech camera product line
Full waveform capture 12-bit Optech IWD-2 Intelligent Waveform Digitizer (optional)
Power requirements 28 V; 300 W; 12 A
Dimensions and weight Sensor: 340 x 340 x 250 mm, 27 kg; PDU: 415 x 328 x 100 mm, 6.5 kg
Operating temperature 0 to +35°C
Relative humidity 0-95% non-condensing